• MPPT algorithm, conversion rate over 99%, fast response
• Remote monitoring, module resistant to extreme conditions, easy to operate and maintain
• Multi scenario adaptation, peak valley arbitrage, promoting energy transformation
KEY STRENGTHS
• Support on/off-grid AC coupling function
• Support intelligent load management (customized)
• Support three-phase and multi-machine parallel connection
• Customizable Remote Upgrade Function for BMS (Based on CAN Protocol)
Model | ![]() R-4KSL
|
|
PV input data | ||
Max. PV input power (kW) | 6 | |
Max. PV input voltage (V) | 550 | |
Start-up voltage (V) | 100 | |
MPPT voltage range (V) | 100~430 | |
Rated PV input voltage (V) | 360 | |
No. of MPPT trackers | 2 | |
No. of strings per MPPT tracker | 1/1 | |
Max. input current per MPPT (A) | 16/16 | |
Max. short-circuit current per MPPT (A) | 24/24 | |
![]() |
||
Battery type | Lithium-ion / Lead-acid | |
Max. charge / discharge power (kW) | 4 | |
Battery voltage range (V) | 40~58 | |
Rated battery voltage (V) | 48 | |
Max. charging / discharging current (A) | 80/80 | |
Rated charge / discharge current (A) | 80/80 | |
Battery charging strategy | Self-adaption to BMS | |
BMS communication | CAN | |
AC output data (grid side) | ||
Rated output power (kW) | 4 | |
Max. apparent output power (kVA) | 4.4 | |
Max. apparent input power(kVA) | 4.4 | |
Rated grid voltage (V) | 230 | |
Grid voltage range (V) | 176~270 | |
Grid input voltage (V) | 230 | |
Rated grid frequency (Hz) | 50/60 | |
Grid frequency range(Hz) | 47~61 | |
Rated output current (A) | 17.4 | |
Max. AC output current (A) | 19.1 | |
Max. apparent input current (A) | 19.1 | |
Power factor | >1 (0.8 leading ~ 0.8 lagging) | |
Max. grid passthrough current(A) | 26.08 | |
THDi | <3% | |
Grid type | L+N+PE | |
AC output data (back-up) | ||
Rated output power (kW) | 4 | |
Max. apparent output power (kVA) | 4.4 | |
Rated output voltage (V) | 230 | |
Rated output frequency (Hz) | 50/60 | |
Rated output current (A) | 17.4 | |
Max. AC output current (A) | 19.1 | |
Peak output power | ≥110%, 10mins; ≥120%, 1min; ≥130%, 1s; ≥150%, 100ms | |
Back-up switch time (ms) | <20 | |
THDu | <3% | |
Protection | ||
Supported protection | PV reverse polarity protection, Anti-islanding protection, Ground fault protection, Leakage current protection, Insulation resistance detection, Backup output short circuit protection, AC under-voltage protection, AC output over-current protection, AC over-voltage protection |
|
Surge protection | DC Type III / AC Type III | |
Over voltage category | DC Type III / AC Type III | |
Certifications and standards | ||
Certificates | ENIEC 61000-6-1:2019, EN IEC 61000-6-3:2021; EN 62109-1:2010; EN 62109-2:2011 | |
General data | ||
Ingress protection | IP65 | |
Operating temperature range (℃) | -25~+60 | |
Cooling | Natural convection | |
Relative humidity | 0-95% (non-condensing) | |
Operating altitude (m) | 0~2,000(derating over 2,000) | |
Dimensions W*D*H (mm) | 476×215×477 (without generator port); 476×215×510 (with generator port) | |
Weight (kg) | 20.5 (without generator port); 20.7 (with generator port) | |
Topology (solar / battery) | Transformerless / Transformerless | |
Noise emission (dB) | <35 | |
PV connection terminals | MC4 | |
Display and communication | ||
Display | LCD | |
Communication | RS485/CAN |